Popular product


The Hydrun Pressure Maintenance Unit is a fully automatic unit that regulates system pressure via a motor valve and a soft-start pressure maintenance pump.
The unit uses the motor valve and the soft-start pump to maintain a constant and stable pressure.
The pressure control unit is designed to manage expansion in heating and cooling systems a smooth and responsive manner. The unit requires only a pressure setpoint—the rest is handled automatically.
Clear connection logic and preset values reduce on-site time.
Proven, service-friendly components from Grundfos, Danfoss, and Schneider Electric.
Modbus TCP, RTU, and BACnet for alarms, status, and logging directly to DDC/BMS as standard.
The unit can be installed with both open and closed expansion vessels.
Function and performance verified in independent tests by Research Institutes of Sweden.
Swedish manufacturing with traceable quality, short lead times, and quick access to spare parts.

Model
HY-P-90
Previous name: Soft-X 90
Previous item no.: HL1069
Max operating pressure: 9 bar
Pressure class: 10 bar
Operating temperature: 0-70°C
Voltage: 230V single-phase
Fuse: 10 A
Power: 0.75 kW
Communication: Modbus TCP, RTU and BACnet
Media: Glykol <50%, Etanol <29%
Connections: 22CU/DN25
Dimensions: D:2 x W:500 x H:750mm
Weight: 26.4 kg
Model
HY-P-90-AF (Autofill)
Previous name: Soft-X 90A
Previous item no.: HL1069A
Max operating pressure: 9 bar
Pressure class: 10 bar
Operating temperature: 0-70°C
Voltage: 230V single-phase
Fuse: 10 A
Power: 0.75 kW
Communication: Modbus TCP, RTU and BACnet
Media: Glykol <50%, Etanol <29%
Connections: 22CU/DN25
Dimensions: D:2 x W:500 x H:750mm
Weight: 26.4 kg
Model
HY-P-40
Previous name: Soft-X 40
Previous item no.: HL1060
RSK no.: 553 64 06
Max operating pressure: 4 bar
Pressure class: 10 bar
Operating temperature: 0-70°C
Voltage: 230V single-phase
Fuse: 10 A
Power: 0.75 kW
Communication: Modbus TCP, RTU and BACnet
Media: Glykol <50%, Etanol <29%
Connections: 22CU/DN25
Dimensions: D:250 x W:500 x H:750mm
Weight: 22.5 kg
Model
HY-P-55
Previous name: Soft-X 55
Previous item no.: HL1067
RSK no.: 553 30 35
Max operating pressure: 5.5 bar
Pressure class: 10 bar
Operating temperature: 0-70°C
Voltage: 230V single-phase
Fuse: 10 A
Power: 0.75 kW
Communication: Modbus TCP, RTU and BACnet
Media: Glykol <50%, Etanol <29%
Connections: 22CU / DN25
Dimensions: D:250 x W:500 x H:750mm
Weight: 23.8 kg
Model
HY-P-70
Previous name: Soft-X 70
Previous item no.: HL1068
RSK no.: 553 30 36
Max operating pressure: 7 bar
Pressure class: 10 bar
Operating temperature: 0-70°C
Voltage: 230V single-phase
Fuse: 10 A
Power: 0.75 kW
Communication: Modbus TCP, RTU and BACnet
Media: Glykol <50%, Etanol <29%
Connections: 22CU / DN25
Dimensions: D:250 x W:500 x H:750mm
Weight: 25.7 kg
Model
HY-P-70-AF (Autofill)
Previous name: Soft-X 70A
Previous item no.: HL1068A
RSK no.: 553 30 38
Max operating pressure: 7 bar
Pressure class: 10 bar
Operating temperature: 0-70°C
Voltage: 230V single-phase
Fuse: 10 A
Power: 0.75 kW
Communication: Modbus TCP, RTU and BACnet
Media: Glykol <50%, Etanol <29%
Connections: 22CU / DN25
Dimensions: D:250 x W:500 x H:750mm
Weight: 25.7 kg
Model
HY-P-55-AF (Autofill)
Previous name: Soft-X 55A
Previous item no.: HL1067A
RSK no.: 553 30 36
Max operating pressure: 5.5 bar
Pressure class: 10 bar
Operating temperature: 0-70°C
Voltage: 230V single-phase
Fuse: 10 A
Power: 0.75 kW
Communication: Modbus TCP, RTU and BACnet
Media: Glykol <50%, Etanol <29%
Connections: 22CU / DN25
Dimensions: D:250 x W:500 x H:750mm
Weight: 23.8 kg
Model
HY-P-40-AF (Autofill)
Previous name: Soft-X 40A
Previous item no.: HL1060A
RSK no.: 553 30 34
Max operating pressure: 4 bar
Pressure class: 10 bar
Operating temperature: 0-70°C
Voltage: 230V single-phase
Fuse: 10 A
Power: 0.75 kW
Communication: Modbus TCP, RTU and BACnet
Media: Glykol <50%, Etanol <29%
Connections: 22CU/DN25
Dimensions: D:250 x W:500 x H:750mm
Weight: 22.5 kg